Professional chimney service

A Seismic Retrofit Planned Together With Your Fireplace Upgrade

Pricing Chimney Seismic Retrofit?

Inserts and Upgrades Our Focus
Firebox Measured Before Any Pick
Options Compared in Writing
Photos With Every Report
Written Quote Before Work
Based in Bell Gardens
Inserts and Upgrades Our Focus
Firebox Measured Before Any Pick
Options Compared in Writing
Photos With Every Report
Written Quote Before Work
Based in Bell Gardens

On This Visit

An unreinforced brick chimney is heavy and stands on its own, which is why so many came down in the 1994 Northridge quake. A retrofit ties it back. Depending on the stack, that can mean steel straps and angle bracing fixed to the framing, or taking the top down to the roofline and laying it back up with steel inside. If an insert is planned, its liner can go in during the same work.

Stack and its tie to the house checked first
Steel straps fixed to roof and wall framing
Angle bracing on tall stacks
Top relaid with steel where bracing is not enough
Liner work combined in the same visit

Why Brick Chimneys Fail in a Quake, and the Usual Fixes

Southeast Los Angeles County knows quakes well. Whittier Narrows in 1987 was centred close to Santa Fe Springs and Bell Gardens, and Northridge in 1994 shook the whole basin. In both, brick chimneys were among the most common damage, and the pattern was the same each time. A brick chimney with no steel inside it is heavy and stiff, while the house beside it is wood and flexes. When the ground moves, they sway at different rates, and the chimney breaks where it is weakest, usually at the roofline or just above it. The top then drops onto the roof, into the yard or down through the ceiling. Older chimneys with worn mortar break more easily still. A retrofit does not make a chimney quake proof, and we will never say it does, but it lowers the odds that the top comes loose and the damage it can do if it does.

The fixes come in a few general kinds, and which one fits depends on the chimney and on your fireplace plans. Bracing adds steel supports from the upper chimney down to the roof structure, holding the top in place. Straps wrap the chimney and fix it to the house at one or more floor or ceiling levels, so the two move together instead of apart. A rebuild takes the brick above the roof down and replaces it, either with new reinforced brick tied into the house or with a lightweight framed top clad to match and carrying a metal flue inside. The three differ in price, in how the stack looks from the street afterward, and in which appliances it can vent later. We describe them in plain terms on the quote, with what each one would mean for your house, and leave the choice with you.

Retrofit and Upgrade in the Same Plan

A retrofit and a fireplace upgrade affect each other, so they belong in one plan. A lightweight rebuilt top needs a metal flue inside it, which suits an insert or a pellet unit and its liner well, and is less suited to keeping open wood fires in the old tile. Bracing and straps leave the flue as it is, so a liner for a new insert can still drop straight down. A full reinforced brick rebuild can be built around whichever flue you want. We set out each option with the fireplace you plan, side by side: the retrofit cost, the liner or flue it needs, and how it changes the look. That way you pay once for the roof work and the scaffolding, and the new top is built to hold the liner plate and cap from the start rather than cut to fit them later. Owners selling a house sometimes do the retrofit first and hand the paperwork to the buyer.

The visit starts with the chimney itself. We look at the brick and mortar above and below the roof, the state of the crown, how the chimney meets the house, and the attic framing near it. A Level 2 at $380 is often the right first step, since its camera shows cracks inside the flue that point to old quake damage. The written quote then lists the method we recommend and any we think would also work, the extent of brick to come down if a rebuild is part of it, how the chimney is fixed to the structure, and the flue or liner included. We do not cite code sections or promise rebates on the quote, and we suggest you ask your insurer or the city about either. To start, use the form and describe the chimney, how tall it stands above the roof and whether it showed damage after any past quake.

How Bosworth Chimney Solutions Plans the Job

Measured First

Opening, hearth and flue sized before advice

Side by Side

Two or three options with trade-offs listed

Priced in Writing

Unit, liner and labor named before any yes

Photo Record

Pictures of what we found, kept with the quote

Where Bosworth offers chimney seismic retrofit

Open a city for the local version: homes common there, burn rules and weather that shape the choice, and the ZIP codes we cover.

Full coverage list

Nothing matched. Try the next town over or a ZIP code.

Other Jobs We Plan

Chimney Sweep

Flue brushed and the smoke shelf emptied, with the firebox measured for any insert you may add later.

Details →

Chimney Inspection

A Level 1 look at each reachable part, graded so you can weigh a fix, an upgrade or leaving it alone.

Details →

Chimney Repair

Cracks, open joints and loose brick mended, scoped so the fix also suits any heater you plan to add.

Details →

Fireplace Inspection

Firebox, hearth, damper and surround looked over, with an eye on whether the opening can take an insert.

Details →

Fireplace Repair

Cracked firebrick, a tired damper or a broken hearth fixed, whether you keep the fire open or plan an insert.

Details →

Chimney Level 2 Inspection

Flue video plus attic and roof checks, booked before a sale, after a quake, or ahead of a new insert.

Details →

Chimney Cap Installation

Stainless or copper caps with ember mesh, sized on the roof, or a liner top once an insert goes in.

Details →

Chimney Flashing Repair

Leaks where roof meets chimney traced, then sealed with new step and counter metal set into the joints.

Details →

Chimney Masonry Repair

Open joints repointed, flaking bricks replaced and the stack made fit to carry a new liner and cap.

Details →

Chimney Rebuilds

A stack past patching taken down until the courses below are solid, then laid back up with room for a liner.

Details →

Fireplace Cleaning

Ash, soot and smoke stain cleared from the firebox, doors and surround, with the opening measured on request.

Details →

Gas Fireplace Cleaning

Gas inserts and log sets serviced once a year: burner, pilot, media and glass cleaned, vent checked.

Details →

Gas Fireplace Repair

Pilots that drop, burners that will not light and dead remotes, traced to the failed part on inserts and log sets.

Details →

Fireplace Remodel

New surround, mantel and hearth drawn around the insert going in, so face and heater fit together.

Details →

Fireplace Inserts

A sealed wood, gas or pellet unit set into your fireplace and lined to the top, so the room gets heat, not a draft.

Details →

Pellet Stove Repair

Pellet stoves and pellet inserts that quit feeding, lighting or burning, tested part by part, vent cleaned.

Details →

Wood Stove Repair

Seals, glass, baffles and firebrick on wood stoves and wood inserts renewed, and the flue hookup checked.

Details →

Gas Logs

Vented or vent-free log sets weighed against an insert for your fireplace, then fitted with line and controls.

Details →

Chimney Crown Repair

Cracked or crumbling crowns sealed, patched or cast new, so rain stops soaking the top of the stack.

Details →

Dryer Vent Cleaning

Lint cleared from the duct between dryer and outside hood, so loads dry faster and the duct runs cooler.

Details →

Chimney Liner Installation

Stainless liners sized for the insert, stove or gas unit going in, run from the appliance to a new top.

Details →

Chimney Leak Repair

Water in the firebox, on the ceiling or down the wall traced to its source and fixed at that point.

Details →

Chimney Waterproofing

A breathable sealer on clean, sound brick, so winter rain beads off the stack instead of soaking in.

Details →

Chimney Damper Repair

Throat dampers freed or replaced, or a top-mount damper fitted, so the flue closes when the fire is out.

Details →

Chimney Chase Cover

Rusted or flat chase tops on framed chimneys replaced with stainless covers shaped to shed water.

Details →
Call (323) 524-5369