Professional chimney service

Pellet Stove Repair for Units That Will Not Light, Feed or Stay Lit

Pricing Pellet Stove Repair?

Inserts and Upgrades Our Focus
Firebox Measured Before Any Pick
Options Compared in Writing
Photos With Every Report
Written Quote Before Work
Based in Bell Gardens
Inserts and Upgrades Our Focus
Firebox Measured Before Any Pick
Options Compared in Writing
Photos With Every Report
Written Quote Before Work
Based in Bell Gardens

On This Visit

A pellet unit depends on a chain of small parts: auger motor, hopper switch, igniter, combustion blower, room fan, sensors and the board that runs them. When one fails, the whole stove quits. We read any stored fault, test the parts in the order the stove uses them, and clean the vent and ash traps behind most shutdowns. Each failed part is named and priced before a new one goes in.

Stored fault codes read first
Auger motor and hopper switch tests
Igniter and blower checks
Ash traps and vent run cleaned
Failed parts priced before replacement

How a Pellet Stove Fails, Part by Part

Inside a pellet stove or pellet insert, a screw at the base of the hopper turns on a timer and drops pellets down a chute into a small burn pot. A hot rod or element lights them at start up. One fan moves the air the fire needs and carries the smoke out through the vent; a second fan blows warm air from around the firebox into the room. A control board runs all of it, and a few safety switches tell the board when to shut down, such as when the stove overheats or the vent pressure drops. Because every part depends on the others, one fault shows up in ways that look unrelated. A stove that lights and then dies after a few minutes may have a blocked vent, a weak exhaust fan, a burn pot full of clinker, or a switch that has failed. The same symptom has several causes, so we test rather than guess.

The most common repairs, in rough order, are these. Igniters wear out and stop lighting the pellets, so the stove fills the pot and shuts down. The feed screw jams on a long pellet or on fines that have packed into the chute, or its motor fails. The exhaust fan slows with ash on its blades and bearings, and the stove senses poor draft and stops. The room fan gets noisy. Gaskets on the door and ash pan go flat and let in air that confuses the burn. Control boards fail less often, and usually after a power surge. Pellet quality matters too: wet or dusty bags leave more ash and clinker and make the stove run worse, and we will tell you if that is part of it. We carry the common igniters, fans and gaskets for popular brands and price any part before it goes in.

Cleaning, the Vent and When to Replace

Most pellet stove trouble starts with ash. The burn pot, the heat exchanger tubes, the ash traps behind the firebox walls and the exhaust fan housing all fill up through a season, and the vent pipe collects fine ash along its length. Owners empty the pot and pan, but the hidden passages need a full service, and we do one each year or every couple of tons of pellets, whichever comes first. On every repair visit we clean those passages and brush the vent, because a stove fixed but left choked will be back to its old faults within weeks. Pellet vents in Bell Gardens and South Gate are often short runs straight through an outside wall, and the cap at the end catches leaves and wasp nests. Pellet inserts that vent up an old chimney have a liner, and its connection at the top needs checking for a tight seal.

Pellet stoves last well with care, but there comes a point where repair stops making sense. Older units from makers who have closed can need boards and motors that are no longer stocked. Bodies rust where the stove sat in a damp spot. We price the repair, and if the stove is close to that point we price a replacement next to it, whether a new pellet stove, a pellet insert, or for some owners a gas insert that removes the fuel handling entirely. Pellet units and their venting are quoted in writing after we see the space, since vent runs differ so much. To book, use the form and give the brand and model from the plate on the back or under the hopper lid, and describe what the stove does from the moment you press start. That account alone points to the fault more often than not.

How Bosworth Chimney Solutions Plans the Job

Measured First

Opening, hearth and flue sized before advice

Side by Side

Two or three options with trade-offs listed

Priced in Writing

Unit, liner and labor named before any yes

Photo Record

Pictures of what we found, kept with the quote

Other Jobs We Plan

Chimney Sweep

Flue brushed and the smoke shelf emptied, with the firebox measured for any insert you may add later.

Details →

Chimney Inspection

A Level 1 look at each reachable part, graded so you can weigh a fix, an upgrade or leaving it alone.

Details →

Chimney Repair

Cracks, open joints and loose brick mended, scoped so the fix also suits any heater you plan to add.

Details →

Fireplace Inspection

Firebox, hearth, damper and surround looked over, with an eye on whether the opening can take an insert.

Details →

Fireplace Repair

Cracked firebrick, a tired damper or a broken hearth fixed, whether you keep the fire open or plan an insert.

Details →

Chimney Level 2 Inspection

Flue video plus attic and roof checks, booked before a sale, after a quake, or ahead of a new insert.

Details →

Chimney Cap Installation

Stainless or copper caps with ember mesh, sized on the roof, or a liner top once an insert goes in.

Details →

Chimney Flashing Repair

Leaks where roof meets chimney traced, then sealed with new step and counter metal set into the joints.

Details →

Chimney Masonry Repair

Open joints repointed, flaking bricks replaced and the stack made fit to carry a new liner and cap.

Details →

Chimney Rebuilds

A stack past patching taken down until the courses below are solid, then laid back up with room for a liner.

Details →

Fireplace Cleaning

Ash, soot and smoke stain cleared from the firebox, doors and surround, with the opening measured on request.

Details →

Gas Fireplace Cleaning

Gas inserts and log sets serviced once a year: burner, pilot, media and glass cleaned, vent checked.

Details →

Gas Fireplace Repair

Pilots that drop, burners that will not light and dead remotes, traced to the failed part on inserts and log sets.

Details →

Fireplace Remodel

New surround, mantel and hearth drawn around the insert going in, so face and heater fit together.

Details →

Fireplace Inserts

A sealed wood, gas or pellet unit set into your fireplace and lined to the top, so the room gets heat, not a draft.

Details →

Wood Stove Repair

Seals, glass, baffles and firebrick on wood stoves and wood inserts renewed, and the flue hookup checked.

Details →

Gas Logs

Vented or vent-free log sets weighed against an insert for your fireplace, then fitted with line and controls.

Details →

Chimney Seismic Retrofit

Straps, bracing or a partial rebuild that tie a brick stack to the house so it is less likely to fall in a quake.

Details →

Chimney Crown Repair

Cracked or crumbling crowns sealed, patched or cast new, so rain stops soaking the top of the stack.

Details →

Dryer Vent Cleaning

Lint cleared from the duct between dryer and outside hood, so loads dry faster and the duct runs cooler.

Details →

Chimney Liner Installation

Stainless liners sized for the insert, stove or gas unit going in, run from the appliance to a new top.

Details →

Chimney Leak Repair

Water in the firebox, on the ceiling or down the wall traced to its source and fixed at that point.

Details →

Chimney Waterproofing

A breathable sealer on clean, sound brick, so winter rain beads off the stack instead of soaking in.

Details →

Chimney Damper Repair

Throat dampers freed or replaced, or a top-mount damper fitted, so the flue closes when the fire is out.

Details →

Chimney Chase Cover

Rusted or flat chase tops on framed chimneys replaced with stainless covers shaped to shed water.

Details →

Insert and repair guides from Bosworth Chimney Solutions

Call (323) 524-5369