A Fireplace Inspection That Starts at the Hearth
Pricing Fireplace Inspection?
Tell us what the fireplace or chimney has now and what you hope to change. We reply with the next step and its cost.
On This Visit
Before anyone talks about inserts, the fireplace itself has to pass. We look at the firebox brick and joints, the lintel across the opening, the damper and throat, the hearth extension, and how close the mantel and trim sit to the fire. Then we take the opening sizes an insert maker asks for. The written result says whether the fireplace is ready to burn, ready to upgrade, or needs work first.
What We Look At on the Room Side
A fireplace inspection is the half of a chimney check you can stand in front of. We look at the firebox brick and mortar joints for cracks and gaps, the back wall where the heat hits hardest, the damper and its frame, the lintel bar over the opening, and the hearth extension in front of it. Hearth size matters: the floor in front of the opening has to stay clear of wood flooring and rugs by a set distance, and older houses sometimes had the hearth trimmed during a floor remodel. We measure it. We check glass doors for cracked panes and loose frames, and the mantel and trim for clearance from the opening. For gas logs we look at the burner, the log placement and the damper clamp. For an insert we check the surround panels, door gasket, glass and blower. All of this is part of a Level 1 for $53, written up for you.
Many of the faults we find on the room side are small and cheap. A loose firebox brick, a missing damper handle, a glass door that will not latch. Others matter more than they look. A crack running through the back wall of the firebox lets heat reach the framing behind it. A hearth that was shortened puts the floor too close to stray embers. On a gas log set, logs placed in the wrong spots throw soot onto the face of the fireplace and make the flame burn dirty. We list each finding plainly, with what it means for safe use, and keep fixes as a separate quote. Nothing is repaired on the spot without your go ahead, and nothing is called urgent unless it is. You get a page you can read in a few minutes and act on when you choose.
Using the Inspection to Choose an Upgrade
The room side tells us a lot about what the fireplace can become. The opening size decides which inserts fit, and an insert needs a little room around it for the surround panels to sit flat. The hearth depth decides whether a stove or insert with a front shelf will clear the floor. The damper decides how a gas log set gets vented, or whether it comes out for a liner. The state of the firebox decides whether it can carry the weight and heat of a wood insert. We write these measurements and notes into the inspection when you ask, set out so you can compare an insert, a pellet unit and gas logs side by side. That makes the next conversation, with us or any installer, start from numbers rather than guesses about your own fireplace.
If the room side looks sound but the flue is a question mark, the next step for an upgrade is usually a Level 2 at $380, which films the inside of the chimney. We say so when the inspection points that way, and not otherwise. Owners in Bell Gardens, South Gate and Los Angeles who are only lighting the fireplace for the holidays may need nothing beyond the Level 1. To book, use the form and say what is in the fireplace today, what you are thinking of putting in, and whether there are glass doors or a mantel close to the opening. If there is an existing insert or gas set, the brand name from the label inside the lower panel helps us bring the right parts list and the right manual for that model.
How Bosworth Chimney Solutions Plans the Job
Measured First
Opening, hearth and flue sized before advice
Side by Side
Two or three options with trade-offs listed
Priced in Writing
Unit, liner and labor named before any yes
Photo Record
Pictures of what we found, kept with the quote
Where Bosworth offers fireplace inspection
Open a city for the local version: homes common there, burn rules and weather that shape the choice, and the ZIP codes we cover.
CA
Fireplace Inspection in Bell Gardens
Small houses went up on subdivided farmland here, many built by Dust Bowl migrants, and roughly 3 in 10 homes still predate 1950. An old brick flue like that gets two plans from us, side by side: stainless liner for the open hearth, or a sealed insert.
Open the city pageCA
Fireplace Inspection in South Gate
Close to half of all homes here were standing by 1950, built for workers at the big plants. On those short brick chimneys we put two upgrade paths next to each other: a vented gas insert on a new liner, or a wood insert sized to the room.
Open the city pageCA
Fireplace Inspection in Santa Fe Springs
Industry claims most of the city, and houses cluster in pockets of modest postwar stucco ranches, with hardly any built before 1950. A 1960s masonry fireplace in one of those ranches fits a gas insert with its own liner nicely.
Open the city pageCA
Fireplace Inspection in Los Angeles
Fireplaces here run from Angelino Heights Victorians to San Fernando Valley ranch tracts. We match the option to the house: a slim liner for an old brick flue, a gas insert for a ranch firebox, a pellet unit where wood smoke is unwelcome.
Open the city pageOther Jobs We Plan
Chimney Sweep
Flue brushed and the smoke shelf emptied, with the firebox measured for any insert you may add later.
Details →Chimney Inspection
A Level 1 look at each reachable part, graded so you can weigh a fix, an upgrade or leaving it alone.
Details →Chimney Repair
Cracks, open joints and loose brick mended, scoped so the fix also suits any heater you plan to add.
Details →Fireplace Repair
Cracked firebrick, a tired damper or a broken hearth fixed, whether you keep the fire open or plan an insert.
Details →Chimney Level 2 Inspection
Flue video plus attic and roof checks, booked before a sale, after a quake, or ahead of a new insert.
Details →Chimney Cap Installation
Stainless or copper caps with ember mesh, sized on the roof, or a liner top once an insert goes in.
Details →Chimney Flashing Repair
Leaks where roof meets chimney traced, then sealed with new step and counter metal set into the joints.
Details →Chimney Masonry Repair
Open joints repointed, flaking bricks replaced and the stack made fit to carry a new liner and cap.
Details →Chimney Rebuilds
A stack past patching taken down until the courses below are solid, then laid back up with room for a liner.
Details →Fireplace Cleaning
Ash, soot and smoke stain cleared from the firebox, doors and surround, with the opening measured on request.
Details →Gas Fireplace Cleaning
Gas inserts and log sets serviced once a year: burner, pilot, media and glass cleaned, vent checked.
Details →Gas Fireplace Repair
Pilots that drop, burners that will not light and dead remotes, traced to the failed part on inserts and log sets.
Details →Fireplace Remodel
New surround, mantel and hearth drawn around the insert going in, so face and heater fit together.
Details →Fireplace Inserts
A sealed wood, gas or pellet unit set into your fireplace and lined to the top, so the room gets heat, not a draft.
Details →Pellet Stove Repair
Pellet stoves and pellet inserts that quit feeding, lighting or burning, tested part by part, vent cleaned.
Details →Wood Stove Repair
Seals, glass, baffles and firebrick on wood stoves and wood inserts renewed, and the flue hookup checked.
Details →Gas Logs
Vented or vent-free log sets weighed against an insert for your fireplace, then fitted with line and controls.
Details →Chimney Seismic Retrofit
Straps, bracing or a partial rebuild that tie a brick stack to the house so it is less likely to fall in a quake.
Details →Chimney Crown Repair
Cracked or crumbling crowns sealed, patched or cast new, so rain stops soaking the top of the stack.
Details →Dryer Vent Cleaning
Lint cleared from the duct between dryer and outside hood, so loads dry faster and the duct runs cooler.
Details →Chimney Liner Installation
Stainless liners sized for the insert, stove or gas unit going in, run from the appliance to a new top.
Details →Chimney Leak Repair
Water in the firebox, on the ceiling or down the wall traced to its source and fixed at that point.
Details →Chimney Waterproofing
A breathable sealer on clean, sound brick, so winter rain beads off the stack instead of soaking in.
Details →Chimney Damper Repair
Throat dampers freed or replaced, or a top-mount damper fitted, so the flue closes when the fire is out.
Details →Chimney Chase Cover
Rusted or flat chase tops on framed chimneys replaced with stainless covers shaped to shed water.
Details →